To be checked:
|
Screw diameter (by measuring) Extraordinary wear (by sight)
|
 |
|
Maintenance Interval:
|
Every 2500 operating hours
|
 |
|
Lower Tolerance:
|
-0,4 mm ( -> postnitriding) -0,6 mm ( -> poss. second postnitriding)
|
 |
|
Instruction:
|
Measuring: Check the external diameter at the above determined measuring points. Register the progression of wear. Register zones of extraordinary wear.
|
 |
|
Note:
|
Wear is superproportional when lower tolerance is surpassed. To avoid superproportional wear replace screw and cylinder at the same time.
|